Heating system Powerflushing and Descaling |
|
Through time, all central heating systems accumulate sludge which detrimentally affects the efficiency of a central heating system and therefore increases the costs of running it. This is especially true with the modern high efficiency Combi and Condensing boilers, which have a much smaller diameter pipework. Additional problems such as a noisy system, rusting radiators, continual venting of radiators and or black water from radiators are all symptoms showing that Powerflushing could help you. Whilst it is rare for a heating system to experience leaks after the flushing process, it is not possible to inspect the system internally before hand, and the need to use a flushing and dispersing chemical for effective cleaning means that occasionally we may find a leak**.
|
|
· Dirty or dark brown water from radiators when emptied or bled of air. · Central heating pump noises or repeated failures. · Radiators are partially or completely cold. · The radiators require regular bleeding. · Noises from the Boiler as it starts up. · Old boilers will have a build up of corrosion |
|
Identifying the Symptoms |

|
Combi Heating System |
|
Open Vent System |
|
The CLEARFLOW® uses low pressure high velocity pump. The power flushing pump is connected into the heating system, either across standard circulator pump couplings, across the tails of one radiator, or wherever is most practicable. The powerful flow, combined with instantaneous flow reverser device, will dislodge and mobilise deposits and corrosion which resist traditional system cleaning methods.
Once the corrosion and sludge deposits have been loosened and mobilised, fresh clean water is forced through the heating system, pushing the contaminated water out through a full bore dump valve to waste. During the CLEARFLOW® process, radiators are individually flushed, without removing or disconnecting them from the system, by directing the full output of the pump through each radiator separately.
At the end of the flushing process, the system contains fresh clean water and reinstatement of the system to normal operation takes only a few minutes.
System flushing will not remedy design or mechanical faults, which should be rectified, but in many cases it will cure the problems caused by these. he kamco powerflush system is connected to your existing heating system by either a radiator of circulation pump.
Results:
· Cure flow and circulation problems · Restore system efficiency · Restore heat output to radiators · Clean the entire system, including under floor pipework · Remove aggressive water; Treatment prevents further corrosion · Cures or prevents boiler noise · Secures a longer life for your boiler |
|
Kamco powerflush system |
|
Trained by |
|
No Call out charge and free Estimates |
|
**Any Estimation or Quotations given allows for a standard power flush only, if any problems arise after the Powerflushing due to the system being in a previous state of neglect or if the system had not been treated with and effective corrosion inhibitor, we will not hold ourselves responsible in any way. Any Further work required would be carried out at an additional cost. |
|
Emergency 24/7 call out |